3.3.2 Set Normal Mode
This funcon is used to measure the temperature of the whole scene and alarm.
Steps
1.
Go to Conguraon → Temperature Measurement → Basic Sengs , and check Enable
Temperature Measurement.
2.
Refer to
Set Thermography Parameters to set the parameters.
3.
Go to
Conguraon → Temperature Measurement → Advanced Sengs , and select Normal.
4.
Congure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is dierent.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps more
than Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps more
than Filtering Time, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the
connected alarm device.
5.
Refer to
Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
6.
Click Save.
The maximum and minimum temperature will be displayed on the live view.
Note
Go to Image → VCA Rules Display to adjust the font size and the temperature color of normal,
alarm and pre-alarm.
3.3.3 Set Expert Mode
Select the temperature measurement rules from Point, Line, or Area and congure parameters,
the device alarms if the alarm rules are met.
Steps
1.
Go to
Conguraon → Temperature Measurement → Basic Sengs , check Enable
Temperature Measurement.
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual