Alarm Input It means the input alarm will trigger a license plate capture and recognion
acon.
Note
When Alarm Input is selected, the alarm input A<-1 will automacally be assigned to trigger
vehicle detecon and its alarm type is always NO.
If the A<-1 alarm input is used to trigger vehicle detecon, it can not be used for other basic
events.
When Alarm Input is selected and saved, previously congured linkage method for A<-1 will
be canceled.
8.
Select the Detecon mode.
9.
Check Remove Duplicated License Plates and set the Time Interval. The default me interval is
4 minutes.
Note
Up to 8 license plates are supported.
10.
Set arming schedule and linkage method. For the arming schedule sengs, refer to Set Arming
Schedule . For the linkage method sengs, refer to Linkage Method Sengs .
11.
Click Save.
10.3.2 Set Mixed-Trac Detecon Rule
The motor vehicles and non-motor vehicles that enter the set lane can be detected, and the
picture of targets can be captured and stored. Alarms will be triggered and captures can be
uploaded.
Before You Start
Go to VCA → VCA Resources , and select Road Trac.
Steps
1.
Go to VCA → Road Trac Detecon Conguraon , and select Mixed-trac Detecon as
detecon type.
2.
Check Enable.
3.
Select the total number of lanes.
4.
Click and drag the lane line to set its posion, or click and drag the line end to adjust the length
and angle of the line.
5.
Adjust the zoom rao of the camera so that the size of the vehicle in the image is close to that of
the red frame. Only the posion of red frame is adjustable.
Note
Only 1 license plate can be captured at one me for each lane.
6.
Select Region and Country/Region.