Hikvision DS-2XC6646G0/P-IZHRS 4MP ANPR Varifocal Anti-Corrosion Bullet Camera

User Manual - Page 90

For DS-2XC6646G0/P-IZHRS.

PDF File Manual, 106 pages, Read Online | Download pdf file

DS-2XC6646G0/P-IZHRS photo
Loading ...
Loading ...
Loading ...
Sensivity Sensivity stands for the percentage of the body part of an acceptable target
that enters the pre-dened region. Sensivity = 100 - S1/ST × 100. S1 stands
for the target body part that goes across the pre-dened region. ST stands for
the complete target body. The higher the value of sensivity is, the more
easily the alarm can be triggered.
Threshold Threshold stands for the threshold for the me of the object loitering in the
region. If the me that one object stays exceeds the threshold, the alarm is
triggered. The larger the value of the threshold is, the longer the alarm
triggering me is.
Detecon
Target
Human and vehicle are available. If the detecon target is not selected, all the
detected targets will be reported, including the human and vehicle.
Target
Validity
If you set a higher validity, the required target features should be more
obvious, and the alarm accuracy would be higher. The target with less obvious
features would be missing.
Figure 10-1 Set Rule
5.
Oponal: You can set the parameters of mulple areas by repeang the above steps.
6.
For the arming schedule sengs, refer to Set Arming Schedule . For the linkage method sengs,
refer to Linkage Method Sengs .
7.
Click Save.
10.2.2 Set Line Crossing Detecon
It is used to detect objects crossing a pre-dened virtual line. If it occurs, the device can take
linkage acons.
Before You Start
Go to VCA → VCA Resource , and select Smart Event.
Steps
1.
Go to VCA → Smart Event → Line Crossing Detecon .
Network Camera User Manual
78
Loading ...
Loading ...
Loading ...