en Installation instructions
40
Explanation
Blind plugs (closure part)
Replacing the cooker burner nozzles
1.
Switch off all of the knobs on the control panel.
2.
Close the gas connection shut-off.
3.
Remove the pan support grids or the pan support
racks and the burner parts.
4.
Use the socket wrench 7 to remove the cooker
burner nozzles.
5.
If your appliance features a wok burner with side ac-
cess, remove the burner nozzle as shown below.
7
7
6.
Look up the burner nozzles in the table. You can
find additional information about this in the section
entitled
→"Technical data – Gas", Page43.
Fit the new nozzles into the appropriate burners.
7.
After replacing the nozzles, check that there are no
leaks. You can find additional information about this
in the section entitled "Leak and function test"
→Page43.
Adjusting or replacing bypass nozzles (small
flame setting)
You can set the minimum flame height for the burners
via the bypass nozzles.
Requirements
¡ Close the gas isolating equipment.
¡ Disconnect the appliance from the power supply.
1.
Switch off all of the knobs on the control panel.
2.
Remove the knobs one by one by holding them
tightly against the control panel and pulling them to-
wards you slightly.
For ovens – converting the appliance from
natural gas to liquid gas
If the appliance was set to natural gas at the time of
delivery (factory setting) (NG: G20, G25) and is now
being converted to liquid gas for the first time (LPG:
G30, G31):
1.
Tighten all of the bypass nozzles in the appliance
clockwise to the limit stop. You can find additional
information about this in the section entitled
→"Removing the control panel", Page41.
2.
Then carry out the steps described in the section
entitled
→"Setting the bypass nozzles", Page42.
3.
Then carry out the steps described in the section
entitled
→"Fitting the control panel", Page42.
Converting the appliance from liquid gas to
natural gas
If you convert the appliance from liquid gas
(LPG:G30,G31) to natural gas (NG:G20,G25) or if
you already carried out this conversion and then undo
this:
1.
Turn all of the bypass nozzles in the appliance anti-
clockwise by 1/2 rotation for the setting. You can
find additional information about this in the section
entitled
→"Removing the control panel", Page41.
2.
Then carry out the steps described in the section
entitled
→"Setting the bypass nozzles", Page42.
3.
Then carry out the steps described in the section
entitled
→"Fitting the control panel", Page42.