130
7.1.5.2 Main View Section
Up to four traces, along with digital readouts of current signal values, signal status
and triggering conditions, can be displayed simultaneously on the main view section
screen.
Each trace has two control features, X-axis and Y-axis, which enable you to adjust
the oscilloscope settings to suit the particular test measurement. If multiple traces
are displayed at the same time, the Y-axis for each trace is adjusted separately while
the X-axis is the same for all traces.
Y-axis the voltage level is recorded on the vertical. It displays on the left side of
the screen.
X-axis time is presented on the horizontal line. It is shown along the bottom of
the screen.
Measurement Overrange Indicator
When the amplitude exceeds the measurement input range, a red overrange
indicator with the message "overrange" is displayed in the top left corner of the
screen. Exceeding the common-mode input range may result in inaccurate
measurements and can lead to severe signal distortion.
Figure 7-37 Sample Overrange Indicator Screen
Select an appropriate scale setting for the signal being sampled to avoid an
overrange condition.