Loading ...
Loading ...
Loading ...
33
Building in
Do not hold or carry the appliance by the door
handle. The door handle cannot hold the weight of
the appliance and may break off.
1. Carefully push the microwave into the box,
making sure that it is in the centre
2. Open the door and fasten the microwave with
the screws that were supplied
Fully insert the appliance and centre it
Do not kink the connecting cable
Screw the appliance into place
The gap between the worktop and the appliance
must not be closed by additional battens
Must be installed above 850mm height
IMPORTANT
Electrical connection
This appliance is supplied with a 15A power cord without
plug. It must be installed by a suitably qualified electrician
in compliance with local regulations and wiring rules. An
accessible all pole isolation switch with contact gap of at
least 3mm must be supplied in installation wiring.
INSTALLATION
INSTALLATION FOR COMPACT OVEN
560
+8
600
560
+8
466
min.
570
568
595
448
min.
850
552
min
100
458
Ventilation area in the base min. 250cm
2
Back
panels
open
Ventilation openings
behind, min. 250cm
2
min 100
20
Min 3.5mm
ventilation gap
below trim
Ventilation grid
6mm packer
Please note packer must be
set back 20mm from front trim
to avoid obstruction of front
vent. Packer must be secured
to base of cabinet.
Cupboard feet
Infill panels are recessed 20mm from the external
cabinet door to accommodate flush fit
Flush fit top view
infill panel
350mm max. length
20mm
600mm
Cupboard
door
Cupboard
door
Loading ...
Loading ...
Loading ...