Gas Dryers
N{)TE : The gas s_rvice to a gas d_er must conform
with the l{_al codes and ordinances or, in the absence
of h_al codes and ordinances, with the latest edition
of the National Fuel Gas Code ANSI Z223.1!NFPA
54 or the CAN/CGA-B149, National Gas Ins_llation
C_e.
L.P (Liquefied Petroleum) Gas, 2,500 Bm/fl :_(93.1
MJ/m_), service musi _ st_pplied at 8M 3 irL water
cohnnn pressure.
NOTE : DO NOT connect the dryer tu L.P. Gas
Service without converting the gas valve.
LP. gas conversion:
- Conversion must _e made by a qualified technician.
See gas valve burner base for gas conversion kit part
nuul_&
NOTE : When connecting to a gas line, an cquipment
shutoff valve must be installed within 6 feet (1.8m) of
the dryer. An 1/8 in. N.P.T. pipe plug must
installt_'l as shown. Refer to Fig.1
Supply line requirements:
Provide a rigid gas supply line to the dryer I{matiorL
- An individual manual shutnff valve nmst be installed
within 1.8m (6 feet) of me drycr in accordance with _le
Natiorml l:uel Gas Code ANSI Z223.1".
When a rigid pit_e is used it should be 1/2 inch IPS.
When acccplable m lhe gas supplier and l(mal codes, 318o
inch approved tubing mW b_,_u,ved for leuglhs under 6.1
m (20 l_2e{).For lcugths over 6.hn (20 lee0, larger
tubing sh{mld b_ used. t}it'_e2jointcoinpom_ds resislani to
the action of L.P. gas must _ used.
To r_uce the risk of gas leaks, fire or
The dryer must be connected to the
type of gas as shown on the nameplate
Iocat_ in the door recess.
Use a new flexible stainless steel
connector.
Use pipe joint compound insoluble in
L.P. (Liquefied Petroleum) Gas, or
Teflon tape, on all pipe threads.
Purge air and sediment from gas supply
line before connecting it to the dryer.
Before tightening the connection, purge
remaining air from gas line to dryer
until odor of gas is detected. This step
is required to prevent a gas valve
contamination.
Do not use an open flame to check for
gas leaks. Use a non-corrosive leak
detection fluid.
Any dis-assembly requiring the u_ of
tools must be performed by an
authorized qualified service _rson,
18