Loading ...
Loading ...
Loading ...
Electrical Connection Options
if your home has: And you will _ Go to Section
connecting to
4-wire receptacle A UL listed, 120/240 4-wire connection:
(NEMATypei4°30R) volt minimum, 30 Power supply cord
amp, dryer power
supply cord*
1, Remove center terminal block screw,
2. Remove appliance ground wire (green) from extemai
ground connector screw, Fasten it under center, silver
colored terminal block screw.
4-wire direct A fused 4-wire connection:
disconnect or circuit Direct Wire
x_ breaker box*
3-wire receptacle
(N EMAty pe 10-30 R)
A UL listed, i20/240 3owire connection:
volt minimum 30 Power supply cord
amp, dryer power
supply cord*
3-wire direct A fused 3owire connection:
disconnect or circuit Direct Wire
"_ breaker box*
if local c_es do not permit the connection of a frame,rounding
conductor to the neutral wire, go to "Optional 3°wire connection"
section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes d_ not permit the use of 3 wire
con nections,
3 4
1.4-wire receptacle (NEMA type 14-30R)
2, 4-prong plug
3, Ground prong
4, Neutral prong
5, Spade terminals with upturned ends
6. 3/4 in. (1.9 cm) UL approved strain relief
7, Ring terminals
1. External ground connector - Dotted line shows
position of NEUTRAL ground wire before _ing
moved to center terminal block _rew_-
2. Center silver-colored terminal block screw
3. Green wire of harness
3, Connect ground wire (green or bare) of power
supply cable to external ground conductor screw.
Tighten screw,
4. Conn_t neutral wire (white or center wire) of power
supply cord to the center, silver colored terminal
screw of the terminal block.
4
I5
--6
1. External ground connector
2. Green or bare copper wire of power supply cord
3. 3/4 in, (1,9 cm) UL-tisted strain relief
4. Center silver-colored terminal block screw
5. Neutral grounding wire (green)
6. Neutral wire (white)
5, Connect the other wires to outer terminal block screws
Tighten screws.
6, Tighten strain relief screws,
7. Insert t_ of terminal block cover into slot of dryer rear
panel Secure cover with hold-down screw
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is r_uired for mobile
homes and where local codes do not permit the use of 3
wire connections.
Direct wire cable must have 5 ft (i ,52 m) of extra length
so dryer can be moved if needed.
Strip 5 in, (12,7 cm) of outer covering from end of cable,
leaving bare ground wire at 5 in. (12.7 cm). Cut Vi2 in.
(3,8 cm) from 3 remaining wires, Strip insulation back i
in. (2.5 cm). Shape ends of wires into a h_k shape.
13
Loading ...
Loading ...
Loading ...