Electric Dryers
(120V/244) Volt, 60 Hertz, 3-Wire Installation)
(120V/208 Volt, 61) Hertz, 3-Wire Installation)
NOTE : The wMng diagram is located inside the
control h{md.
To reducd the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
_ition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22A, and such local
regulations as might apply. It is the
customer's responsibility to have the
wiring and fuses checked by a qualified
electrician to make sure your home has
adequate electrical power to operate the
Grounding Instructions
This duer must be connected to a grounded metal,
permanent wiring system; or an equipmeni:-grounding
couduclor must _ run with the circuit conductors and
connected to the equipment-grounding terminal or
lead on the dryer.
O
O
O
O
The dryer has its own _cnninal block Ihat must be
connected to a sepa'ate branch, 60/lertz, single phase:
circuit, AC (alter_mting current) circuit, tilsed at: 30
Amperes (the circuit must be fused on N)th sides of
the liue). ELECTRICAL SERVICE FOR THE
DRYER SIIOI?LD BE OF MAXIMUM RATE
VOLTAGE LISTED ON THE NAMEPLATE. DO
NOT CONNECT DRYER TO 110, 115, OR 120
VOLT CIRCI!IT. Heating elements are available for
:fieldins{allation in dryers which are to be conected m
electrical service of dift;crent w)lmge than that listed
on namq_late, such as 208 Volt.
If branch circuit m dryer is fifteen i)et (4.50 m) or
less in length, u_= U.L. (Underwriters LaN_ratories)
listed No. 10 A.W.G. wire (copper wire only), or as
rcqaircd by local c(_es. If over fifteen tibet(4.50 in),
use [J.L. (Underwriters I.abomtories) listed No. 8
A.W.G. wire (copper wire only), or as l_.Nuiredby
local codes. Allow sufficient slack in wiring _ dryer
can be moved from its normal location when
necess_uLv.
The ln)wer cord (pigtail) conn_tion between wall
receptacle and dryer terminal block IS NOT supplic-d
with dryer. Type of pigtail and gauge of wire must
confom_ to local codes and with instructions
mentioned on the :li:)llowingpages.
The meth(x.t of wiring the dryer is optional and
subject to k_'a! c_e requirements_ Ret'er to examples
on next page.