IMPORTANT : InstMlation must conform to the
Manufactured Home Construction and Safety Standards,
Title 24 CFR, Part 32-80 or Standa_ CAN/CSA-Z240 MH.
The dryer can _ installed in a manuthctured (moNle)
home by lollowing these instructions:
1. IMPORTANT : Gas drye_ MUST be permanently
attached to the fl{n_rat the time of installation.
2 Elcctrical Connections (Ekctric Drycr Ordy) musl be a
4-wire connection.
3 Venting = Dryer MUST _ exhausled to the outdoors.
To reduce the risk of fire and combustion
gas accumulation, the dryer MUST BE
EXHAUSTED TO THE OUTDOORS. Refer to
_ction on Dryer Exhaust Requirements.
O
I)rycr exhaust duct MUST NOT tcnninme under lhe
lnobik: home.
For protmr olmmtion, it is im[_g}r|ant fllat file dryer has
an _m_ple amount of outside Fresh ai:r. The opening
liar outside air must _ at least 25 in_(1 (Gcm)
When exhzmsting the dryer to the outdoors, Ihe d:ryer
can _ installed with "1" inch clearance at fl_esides
and rear. Clem'ance of the duct from combustible
construction nmst b_ a minimum of 2 inches
(5.08 cm).
Venting nmk_als _e not supplied wifll the dryer
(obtain locally).
The dryer c_m _ exh_mstcd to the outdCx)rs through
the back, left, right or bottom panel. Gas dryeJ_
cannot be exhausted out the right side bccau_ of _le
bumer housing.
The d_3_er exhaust duct must be _curcd to _le mobile
home structure.
Exhaust ducts MIST NOT be connected with sheet
metal screws or fasteners which extend into the duct.
Exhaust dnct must not _ connected to _my other duct,
vent or chimney.
To reduce the risk of fire, the exhaust
duct and weather hood MUST be
fabricated of a material that will not
support combustion. Rigid or flexible
metal pipe is recommended for a clothes
11