MAXIMUM USABLE POWER FOR THE
COOKING ZONES
The cooking zones are controlled by 2 separate
power boards:
The maximum total power per each power
board is 3700 W.
Should the cooking zones of one power board
require more than 3700 W, the last selected
power level has priority and the power of the
other cooking zone is automatically reduced to
the remaining power available.
If this occurs, the cooking zone will display
a ashing gure for about 3 seconds before
automatically displaying the new power level.
This means for example that:
When setting a “Booster” programme for
the second zone, the setting for the other
zone could be reduced to the remaining
power available.
When setting a “Booster” programme for
a zone and then another setting on the
second zone, if the total power exceed
3700 W the “Booster” programme is
deleted and the power reduced to the
maximum power available.
THERMAL PROTECTIONS
The induction hob is tted with safety devices
to protect the electronic system and to protect
each cooking zone from overheating.
In case of overheating, one of the following
automatic functions could be started by the
electronic system:
“Booster” program deleted and power
reduced.
One or more cooking zone switched O󰀨.
Cooling fan motor of the induction unit
switched On.
Fig. 2.10
Controlled by
1st power board
Controlled by
2nd power board