Napoleon BGD36CFGN2 Crystallo Series Direct Vent Natural Gas Fireplace

User Manual - Page 6

For BGD36CFGN2.

PDF File Manual, 132 pages, Read Online | Download pdf file

BGD36CFGN2 photo
Loading ...
Loading ...
Loading ...
6
W415-1361 / 11.28.14
EN
4.1B
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
A
NSI Z223.1 and NFPA 54 in the United States.
A
s long as the required clearance to combustibles is
maintained, the most desirable and bene cial location
for an appliance is in the center of a building, thereby
allowing the most ef cient use of the heat created. The location of windows, doors and the traf c ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
All sections of this manual with BGD36CF(G) are common to BGD36CF, BGD36CFG.
2.3 GENERAL INFORMATION
When the appliance is installed at elevations above 4,500 ft (1371m), and in the absence of speci c recom-
mendations from the local authority having jurisdiction, the certi ed high altitude input rating shall be reduced
at the rate of 4% for each additional 1,000 ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Use only accessories designed for and listed with your speci c appliance.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
RATES AND EFFCIENCES
NG LP
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 17,000 17,000
Max. Output Steady State (BTU/HR) 10,900 10,900
Ef ciency (w/the fan on) 64% 64%
A.F.U.E. (Annual Fuel Utilization Ef ciency) 53% 53%
Min. Inlet Gas Supply Pressure 4.5" (11mb) w.c. 11" (27mb) w.c.
Max. Inlet Gas Supply Pressure 7" (17mb) w.c. 13" (32mb) w.c.
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) w.c. 10" (25mb) w.c.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!