Napoleon BGD36CFGN2 Crystallo Series Direct Vent Natural Gas Fireplace

User Manual - Page 50

For BGD36CFGN2.

PDF File Manual, 132 pages, Read Online | Download pdf file

BGD36CFGN2 photo
Loading ...
Loading ...
Loading ...
50
W415-1361 / 11.28.14
EN
12.2.2 BGD36CFG VENTURI ADJUSTMENT
The alternate access is to remove the glass, glass em-
ber tray and burner from the appliance and then adjust
the air shutter.
NOTE: When removing the glass ember tray make
sure the glass embers are away from the center of
the screen, exposing the burner, before lifting glass
ember tray out.
When replacing burner, absolutely no glass can be in
cup surrounding the ori ce. HINT: If glass falls into cup
and surrounds the ori ce, insert a clean bag into a vacu-
um cleaner and vacuum out glass embers. Replacement
glass embers can be ordered from Wolf Steel Ltd.
CARBON CAN BE DISTRIBUTED IN SURROUNDING LIVING AREA IF THE AIR SHUTTER IS IMPROP-
ERLY ADJUSTED.
THE FRONT OF THE APPLIANCE BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE
COOL COMPLETELY BEFORE CONDUCTING SERVICE.
!
WARNING
NG
LP
BGD36CFG
0
1/4" (6.4mm)
This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
AIR
SHUTTER
OPENING
VENTURI
BURNER
ORIFICE
49.1
It’s important to periodically perform a visual check of the pilot and burner ames.
Compare them to the illustrations provided. If any ames appear abnormal call a
service person.
54.4A
3/8” - 1/2”
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
FLAME SENSOR
(9.5mm - 12.7mm)
12.3 BGD36CFG FLAME CHARACTERISTICS
Loading ...
Loading ...
Loading ...