Operation
www.bora.com
7.2.3 Switching on the delayed automatic
after-run
Continue pressing until power level
n
is displayed
for automatic after-run.
The fan runs in level 1 and switches off automatically
after 10 minutes.
7.2.4 Switching off the cooktop extractor
Press and simultaneously until the fan level
indicator
0
is displayed.
or
Press or several times until the fan level
indicator
0
is displayed.
When the fan level indicator displays
0
, the cooktop
extractor is switched off automatically after a few seconds.
7.3 Pay attention to the filter service
display
If the fan level indicator displays
F
(F = filter service
indicator), this means the activated charcoal filter is used
up (for recirculated air only) and the stainless steel grease
filter needs an overhaul.
If you do not wish to do the filter change yet, e.g. if you
only cook occasionally:
Press or to go into the normal operating mode.
0
is shown in the fan level indicator.
Changing the filter
Switch off the cooktop with integrated cooktop extractor.
Observe all warnings that are described in the
Cleaning chapter.
Replace the activated charcoal filter.
Clean the stainless steel grease filter, the air inlet nozzle,
the air guiding housing and the housing base.
Resetting the filter service display
If the activated charcoal filter was replaced (only for recircu-
lated air) and the stainless steel grease filter was cleaned, it
will be necessary to reset the filter service display.
Switch on the cooktop with integrated cooktop extractor.
The fan level indicator displays
F
.
Press and simultaneously for at least three
seconds until a
0
flashes in the fan level indicator.
After a few seconds,
0
will be displayed permanently.
The filter service display has been reset.
7.2 Operating the cooktop extractor
Prerequisite:
The cooktop with integrated cooktop extractor is
switched on.
Recommendations for an efficient vapour extraction:
Make sure to always use a lid for pots that are
particularly high. This ensures effective vapour
extraction. It also reduces power consumption.
Only operate the cooktop extractor at the minimum
power level required for an effective vapour extraction.
This way, you can improve the performance of the
odour filters during air circulation operation.
Only operate the hob at the minimum power level
required for cooking. This reduces the cooking vapours
and power consumption.
Avoid strong drafts.
7.2.1 Switching on the cooktop extractor
Press or to switch on the cooktop extractor.
0
is shown in the fan level indicator. If no further
input is made, the cooktop extractor will switch off
automatically a few seconds afterwards.
7.2.2 Setting the fan level
Press to increase the fan level.
The following fan level sequence is run through:
Fig. 7.1 Fan level sequence
Press to reduce the fan level. The following fan level
sequence is run through:
Fig. 7.2 Fan level sequence