25
Assembly
www.bora.com
The maximum exhaust air duct length is 6 m.
Planning information for the installation of the
exhaust air ducts are provided in the BORA ventilation
instructions.
Preparing the rear wall of the furniture
Before carrying out the installation at the floor unit,
check the required installation dimensions for the
device and the planned duct system.
Adjust the position of the rear wall according to the
required installation dimensions as necessary.
Extending the exhaust air duct
INFO The exhaust air duct can optionally be
extended by 100 mm to the rear using the
supplied horizontal extension BLAVH1.
Remove the air inlet nozzle and stainless steel grease
filter.
With the glass ceramic panel facing downwards, place
the cooktop onto a clean and protective surface (e.g.
cardboard, packaging material) to prevent damage to
the glass ceramic panel.
3
2
1
Fig. 6.24 Removing the housing base
[1] Housing base
[2] Locks
[3] Air guiding housing
Open the 4 locks [2].
Remove the housing base [1] from the air guiding
housing [3].
> 600
< 430
480
535
105
290
40
Fig. 6.22 Installation dimensions for exhaust air, worktop depth
600 mm
> 700
< 530
580
635
105
290
40
100
Fig. 6.23 Installation dimensions for exhaust air, worktop depth
700 mm
Installation conditions
The rear wall of the floor unit must be adjusted for the
exhaust air duct.
A minimum clearance of 110 mm between the rear
wall of the furniture body and an adjacent piece of
furniture or wall must be observed for the duct.
The exhaust air must be directed to the outside in
appropriate exhaust air ducts.
The minimum cross-section of the exhaust air ducts
must be 176 cm
2
. This equates to a cylindrical tube
with a diameter of 150 mm.