Assembly
www.bora.com
Installation dimensions
735
510 - 570
>800
650
>50
119
>25
90
490
>600
90
117
650
675
< R15
133
119
6x Ø5mm
Fig. 6.9 Dimensions of furniture, recirculated air
> 25
510 - 570
119
> 600
Fig. 6.10 Installation dimensions for recirculated air, worktop
depth 600 mm
6.5 Attaching the sealing tape
2
1
Fig. 6.7 Sealing tape, surface installation
1
2
Fig. 6.8 Sealing tape, ush installation
[1] Black heat-resistant silicone sealing compound
[2] Sealing tape
With surface installation, attach the included seal-
ing tape [2] on the underside of the cooktop before
installing it. Do not leave any gaps.
With flush installation, attach the sealing tape [2] to
the horizontal cutting edge in the worktop cut-out,
even if you seal the cooktop with a silicone sealing
compound [1] or similar.
Note down the type designation and build number of
the cooktop (FD number) on the back of this manual.
Both designations can be found on the nameplate on
the underside of this cooktop.
6.6 Installing the air recirculation
version (BIU)
INFO There must be a minimum clearance of 25 mm
for the vertical return flow aperture.
INFO There must be a return flow aperture of at least
500 cm
2
.
When the cooktop extractor is exclusively used in
recirculated air mode, it is possible to operate it with an
open furnace without any additional safety measures
being required.