Installation Instructions
[] CHECK IGNITION OF SURFACE
BURNERS
Operation of oil cooktop and oven burners should be
checked offer the range and gas supply lines hove
been carefully checked for leaks.
Electric Ignition Models
Select o top burner knob and simultaneously push
in and turn to Lite position. You will hear o clicking
sound indicating proper operation of the spark
module. Once the air has been purged from the
supply lines, burners should light within/4 seconds.
After burner lights, rotate knob out of the Lite position.
Try each burner in succession until oil burners hove
been checked.
Quality of Flames
The combustion quality of burner flames needs to be
determined visually.
(A) Yellow flames--
Call for service
(B) Yellow tips on
outer cones--Normal
for LP gas
(C)Soft blue flames--
Normal for natural
gas
If burner flames look like (A},call for service. Normal
burner flames should look like (B} or (C},depending
on the type of gas you use.
With LPgas, some yellow tipping on outer cones is
normal.
[] CHECKIGNITION OF OVEN BURNER
The oven is designed to operate quietly and
automatically. To operate the oven, set the oven
control to a setting above 200°F.After 30-90 seconds,
the oven burner will ignite and burn until the set
temperature is reached. The oven burner will continue
to cycle on and off as necessary to maintain the
oven at the temperature indicated by the Oven
Control knob.
Electric ignition models require electrical power to
operate. In case of u power outage, the oven burners
on these models cannot be lit manually with u match.
Gas will not flow unless the glow bur is hot.
If the oven is in use when a power outage occurs, the
burner will shut off and cannot be re-lit until power
is restored.