TROUBLESHOOTING
Error Code Cause Solution
E4 Communication Failure
1. The grill will automatically run the shutdown procedure if the grill is still hot. Open
the grill lid and wait until the grill has completed the shutdown procedure and
completely cooled.
CAUTION: Do not unplug the grill or power it o during the shutdown procedure.
2. Once the shutdown procedure is complete, power o the grill and unplug from
power source.
3. Wait one minute, then plug the grill back into the power source and power on the
grill to begin your cook.
E5 Grill is too Hot
1. The grill will automatically run the shutdown procedure if the grill is still hot. Keep
the grill lid closed and wait until the grill has completed the shutdown procedure
and completely cooled.
CAUTION: Do not unplug the grill or power it o during the shutdown procedure.
2. Once the shutdown procedure is complete, power o the grill and unplug from
power source.
3. Open the grill lid and remove the cooking grates, FLAVORIZER bars, heat diuser,
and heat bae from the cookbox.
4. Clean the cookbox and burn pot of any ash or debris using a grill brush or scraper to
direct it into the ash and grease system.
CAUTION: Allow time for the ash and debris to fully extinguish before cleaning the grill.
5. Reinstall the heat bae, heat diuser, FLAVORIZER bars and cooking grates inside
the cookbox.
6. Remove and clean any ash or grease from inside the ash and grease system. Once
cleaned, reinstall the drawer. Replace disposable drip pans as needed.
7. Plug the grill into the power source and power on the grill to begin your cook.
E6 Start Up Failure
1. The grill will automatically run the shutdown procedure if the grill is still hot. Open
the grill lid and wait until the grill has completed the shutdown procedure and
completely cooled.
CAUTION: Do not unplug the grill or power it o during the shutdown procedure.
2. Once the shutdown procedure is complete, power o the grill and unplug from
power source.
3. Open the grill lid and remove the cooking grates, FLAVORIZER bars, heat diuser,
and heat bae from the cookbox.
4. Clean the cookbox and burn pot of any ash or debris using a grill brush or scraper to
direct it into the ash and grease system.
CAUTION: Allow time for the ash and debris to fully extinguish before cleaning the grill.
5. Remove and clean any ash or grease from inside the ash and grease system. Once
cleaned, reinstall the drawer. Replace disposable drip pans as needed.
6. Plug the grill into the power source and power on the grill.
7. Turn and push the dial on the controller to select 400°F as your grill temperature.
8. As the grill starts to preheat, visually inspect the glow plug at the bottom of the
cookbox.
WARNING: Do not touch the glow plug to check if it is hot. If the glow plug is operating
correctly, it will start to glow in color as it heats.
If the glow plug is operating correctly:
9. Reinstall the heat bae, heat diuser, FLAVORIZER bars and cooking grates inside
the cookbox.
If the glow plug is not operating correctly:
The grill will remain cool and will not ignite. Shutdown the grill by pressing and holding
the dial on the controller. Contact the Customer Service Representative in your area
using the contact information on our website for glow plug replacement.