Water and Ice Dispensers
IMPORTANT:
Allow 3 hours for the refrigerator to cool down and chill water.
Allow 24 hours to produce the rst batch of ice. Discard the
rst three batches of ice produced.
The dispensing system will not operate if the left-hand
refrigerator door is open.
Flush the Water System
Air in the water dispensing system can cause the water dispenser
to drip. After connecting the refrigerator to a water source or
replacing the water lter, ush the water system.
Flushing the water dispensing system forces air from the water
line and lter and prepares the water lter for use. Additional
ushing may be required in some households.
NOTE: As air is cleared from the system, water may spurt out of
the dispenser.
1. Using a sturdy container, depress and hold the water
dispenser paddle for 5 seconds.
2. Release the dispenser paddle for 5 seconds. Repeat steps
1 and 2 until water begins to ow.
3. Once water begins to ow, continue depressing and releasing
the dispenser pad (5 seconds on, 5 seconds off) until a total
of 3 gal. (12 L) has been dispensed.
B
A
A. Water dispenser paddle
B. Ice dispenser paddle
Dispensing Calibration
Household water pressure may affect the accuracy of the
Measured Fill feature. So, for optimum performance of your
water dispenser, you must rst calibrate Measured Fill.
IMPORTANT:
Flush the water system before calibrating Measured Fill.
For best results, calibration should be performed when water
is not being used in the house.
1. Place a sturdy measuring cup (1 cup [237 mL] size) on the
dispenser tray centered in front of the ice/water dispenser
paddle.
NOTE: Depending on your model, a measuring cup may be
provided.
A. Water dispenser paddle
B. Ice dispenser paddle
C. Measuring cup (1 cup)
Ensure that you do not have any Measured Fill preset
selected.
2. To enter Calibration Mode, go to Tools > More Modes >
Calibration. Calibration can also be done the rst time the
refrigerator is powered on.
3. Press and hold the water dispenser paddle, as needed, to
dispense water to the 1 cup ll line in the measuring cup.
NOTE: If overlling or spilling occurs, discard the water and
restart the calibration process.
4. When 1 cup of water has been correctly dispensed into the
measuring cup, touch OK to conrm the calibration.