TROUBLESHOOTING
EN
The appliance is equipped with an automatic error-monitoring system to detect and diagnose
problems at an early stage. If the appliance does not function properly or does not function at all,
check the following before you call for service:
Diagnosing Problems
Problem Possible Cause Solutions
Appliance will not operate.
Door is not completely
closed.
Level the appliance again.
Power supply or power
cord is not connected.
Connect the power supply or cord
properly.
Control Lock is activated. Cancel of the Control Lock button.
Fuse is blown or circuit
breaker tripped.
Replace the fuse or reset the circuit
breaker.
Appliance continuously
beeps when the door is
opened, during or right
after a cycle has
completed.
The contents of the
appliance are hot and care
should be used when
placing your hands inside
the appliance.
Close the door until the appliance
and dishes have cooled down. The
beeping will stop if the door is closed
or the interior temperature has
cooled.
Water remains in sump
after completion of cycle.
Drain hose is kinked or
clogged.
Adjust hose or clear blockage.
Water may remain if the
power supply was lost
before normal end of the
course or was manually
disconnected.
Re-start the course.
Sprays arms do not rotate
smoothly.
Holes of spray arms are
blocked by food particles.
Clean the holes of spray arms.
Upper rack is crooked. Rack is poorly adjusted.
See the Height Adjustable Upper
Rack section.
Lamps do not illuminate. Power is not connected. Connect power supply.
There is excessive foam
inside the appliance.
Failure to use the
detergent exclusive for
appliance.
Use the detergent exclusive for
appliance.
An excessive amount of
rinse may cause foam.
Reduce the rinse aid dispensing
level.