Loading ...
Loading ...
Loading ...
38 electrolux.com.au
The freestanding type installation uses the appliance as
supplied, and can be fitted in between cabinets, with
cabinets on one side or without adjacent cabinets. There is
no clearance requirement to adjacent side cabinets.
To ensure cooker stability, the anti-tilt brackets must be
installed, and the end of chain attached to the appliance
must be placed onto the hook attached to the rear wall.
Installation of anti-tilt brackets and hook
Measurements
are to be adjusted
to account for
the thickness of
any skirting board
or tiles coming
between the back
of the appliance
and the wall
Hole location for
hook installation
840mm
376mm
425mm
194mm
Cabinet construction for freestanding installation
The anti-tilt brackets must be secured to the floor at
rear of cavity with an appropriate fastener according
to dimensions in diagram.
The hook is to be secured to the back wall in the
location shown above with an appropriate fastener
capable of withstanding a 10kg load.
Connect services to the appliance prior to placing
into cavity.
To locate appliance, slide into cavity ensuring the rear
left and right foot of appliance are captured by the
anti-tilt brackets.
Before the appliance is fully pushed into position,
place the chain attached to the rear of appliance
onto the wall hook.
895mm
600mm
600mm minimum vertical
clearance from combustible
surfaces
Gas Hob 910mm
(adjustable 910-930mm)
Induction Hob 906mm
(adjustable 906-926mm)
15mm height of trivet
from hob
Anti-tilt Bracket
Chain
900mm
minimum
Wall hook
755mm
900mm
600mm
INSTALLATION OF THE EFEP955SB & EFEP915SB
Loading ...
Loading ...
Loading ...