34 technical specifications electrolux e:line ovens technical specifications electrolux e:line ovens35
Technical specifications
model product dimensions
(hxwxd)mm
electrical connection min.fuse
rating
max.power
rating
max.
current
rating
EOEM61CS 595x596x573 230-240v/50Hz 16A 3.1k W 12.9A
EOEE62CS 595x596x573 230-240v/50Hz 16A 3.1kW 12.9A
EOEE62CK 595x596x573 230-240v/50Hz 16A 3.1k W 12.9A
EOEE63CS 595x596x573 230-240v/50Hz 16A 3.1kW 12.9A
EUEE63CS, EUEE63CK 888x596x573 230-240v/50Hz 25A 5.3kW 2 2.1A
EDEE63CS 1081x596x573 230-240v/50Hz 25A 5.8kW 24.2A
EPEE63CS, EPEE63CK 595x596x573 230-240v/50Hz 16A 3.1kW 12.9A
error code description comment fix
F01 or 01 Door lock sensor alarm This relates to a door lock
failure which is only associated
with the Pyro product
Checkwiring/plugsor
replace door lock
F02 or 02 Door lock actuator alarm
F04 or 04 OvenProbe(PT500)outof
range alarm
This relates to the temperature
sensing probe which may be
outoftolerance,orhaveopen/
short circuit connections
Replace probe
F05or05 OvenProbe(PT500)toohigh
temperature alarm
25 BoardTemperatureSensor
(NTC)toohightemperature
alarm
This relates to the temperature
ofthepowerboardand/orthe
temperature-sensingelement
(NTC)onthepowerboard
Cooling fan not working
or replace powerboard
26 BoardTemperatureSensor
(NTC)outofrangewarning
6 BoardTemperatureSensor
(NTC)outofrangealarm
F08 or 08 Communication alarm This relates to an error in
communication between
thepowerboardandtheIOI
controller. This can occur if
theIOIcontrollerisconnected
while the powerboard is
energised
Reset power. (Minimum of
20 sec.) or check or replace
data cable
F09 or 09 Software compatibility code
alarm
This relates to a mismatch
between powerboard firmware
versionandtheIOIcontroller
firmware version. Most likely
causedbyanun-programmed
powerboard
Replace Powerboard
C1 Telescopic runners fitted Only applies to Pyro product Remove both side racks and
re-startpyrocycle
C3 Door open Only applies to Pyro product Close door and restart pyro
cycle
F03 or 03 EEPROM check sum alarm Relates to the controller Replace Controller
F14 or 14 EEPROM compatibility code
alarm
Relates to the controller Replace Controller
Technical specifications Hard wiring details
1. Remove terminal cover plate from rear panel of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Plastic clips
Plastic clip
securing points
Note:
Other Potential complaints
• Whenthedoorisopenedthefanstops(underbench
only) This is a function of the powerboard to help reduce
the blast of air the customer receives when they open
the door.
• Whenanon-fanmodeisselectedthefanstarts.Most
oven modes have a fast heat up function that uses the
fan,fanelement,andtop(boost)element.Autofast
heat up can be overridden by selecting a temperature
of 120ºC or less, allowing the function to start, then
increasing the temperature to the desired level.
• Thelightstaysonwhenthedoorisclosed,doesnot
turn on when the door is open and the oven is off.
The door switch is not activating due to restricted
travel or broken actuator.
TestMode
• Within10secondsofpoweringupsimultaneouslypress
thetimerbuttonandstart/stoptime‘+’button,thiswill
enter‘TESTMODE’foramaximumof5minutes.
Firstly displayed will be the software version and model
No.Thenusingthefunction‘
^
’and‘v’buttonsscroll
through door lock test (Pyro only) individual element and
light, cooking fan, cooling fan and temperature probe
etc. functions.