V-ZUG Ltd
V-ZUG Ltd, Industriestrasse 66, CH-6302 Zug
[email protected], www.vzug.com
Planning aid
International collection
Laundry room appliances
J001062-R16
30.04.19
7
3
Plumbing in
3.1
Washing machines
Comply with the regulations laid down by the local water supply authority for the layout of the supply pipe and drainage.
General operating conditions
Value Nominal value Minimum Maximum
Mains pressure
(0.1 MPa = 1 bar)
Static 0.3 MPa 0.1 MPa 1.0 MPa
Flowing 0.08 MPa 1.0 MPa
Water hardness
1
0.5 °fH 50 °fH
Water inlet temperature Cold water 5 °C 35 °C
Water inlet G¾"
Drainage cross-section ø internal 57 mm (on-site) ø internal min. 19 mm
1
For special cases with water hardness in excess of 50 °fH, an external water softener is recommended.
Water inlet
Appliance Hose Length Connection Optimal working
pressure
Possible pressure
range
AdoraWash
V2000–V6000
Inlet hose with Aquastop 1.25 m G¾" 0.3 MPa ( 3 bar) 0.1–1.0 MPa (1–10 bar)
Connection to a mixer tap or a continuous flow heater is not permitted!