Planning aid
International collection
Laundry room appliances
J001062-R16
30.04.19
17
5.3
Installation
General condition
To prevent an impermissible rise in temperature and humidity, the room must be min. 20 m
3
in size and sufficiently large in-
let and outlet openings to an adjacent room or to the outside must be available (open windows, ventilation grilles or slots in
the door, ventilation systems). On the other hand there is the possibility of using the waste heat.
Normal bathroom extractor fans are not adequate for optimal room ventilation. They switch off with the light after a preset
after-running time.
Through the heat recovery of the heat pump dryer, heat dissipation is greatly reduced, resulting in the imposition of far fewer de-
mands on the installation room. Heat pump dryers affect their environment like a heater blower with a heat output of approx. 700 W.
All Adora appliances must be mounted on the installation plate supplied. Only in this case is problem-free operation guaran-
teed. The appliances can be levelled by means of adjustable feet.
The room must be kept free of dust and fluff.
Room temperature
Permissible room temperature: 5 °C to 35 °C
The room temperature must be kept between the range of 15–25°C to ensure the economic running of the appliance. A
room temperature of over 35 °C is critical and extends the duration of the individual programmes. High temperatures can
also result in error messages and impair the service life of the appliance.
Ventilation
As a general rule, rooms containing heat pump dryers should be ventilated as these produce a small amount of moisture. For each
heat pump dryer, the passage of exhaust and intake air must be guaranteed. EXHAUST AIR requires INTAKE AIR. At least the same
amount of air must be supplied to as is being extracted from the room.
Ventilation concepts
Installation room volume <20 m
3
:
There must be air inlet and outlet openings (open window, ventilation grille or slits in the
door, ventilation system) to the adjacent room or to the outside.
Operation is trouble-free with an air circulation rate from 15 m
3
/h.
Installation room volume ≥20 m
3
, room kept closed:
Condensation may form on thermal bridges!
The room must be aired (by opening the door to or a window in the room) between con-
secutive drying programmes!