V-ZUG Ltd
V-ZUG Ltd, Industriestrasse 66, CH-6302 Zug
[email protected], www.vzug.com
Planning aid
International collection
Laundry room appliances
J001062-R16
30.04.19
24
7.4
Positioning
The appliance must stand level and stable. Check with a spirit level.
The appliance must not wobble in case of a crosswise load.
The floor surface must be clean, dry, free of floor wax residue and other lubricating coatings so that the appliance does not slide
away! Do not use pieces of wood, cardboard or the like to compensate for any small irregularities in the floor surface (a floor attach-
ment plate set no. 81131132 may be used to secure the appliance). If, for reasons of space, it is not possible to avoid installing the
appliance directly next to a gas or coal-fired appliance: install a thermal insulation panel between the cooker and the appliance
(85×57cm) which must have an aluminium film on the side against the cooker.
Positioning in a niche
The Adorina appliances have 4 adjustable feet to correct for uneven or sloped floors. The height adjustment allows for a 6–15 mm
gap from the bottom side of appliance to the floor.
Niche
Decor panel
A
A
600
1
B
Cut-out for connections 1 (left or right):
≥50 × 100mm or
≥80 × 80mm
Niche depth A: ≥584mm
Niche height B: ≥825mm
Appliance decor panel or appliance panel flush with neigh-