FIGURE 4
MANOMETER
FRONT
PANEL
4. Turn on and zero manometer. See Figure 4.
5. Plug in dryer or reconnect power.
6. Turn on gas supply.
7. Set dryer cycle to time dry, high heat and turn on dryer.
8. After ignition, verify gas inlet pressure is between
8" (203 mm) and 13" (330 mm) water column.
9. Turn off dryer.
10. Unplug dryer or disconnect power.
11. Turn off gas supply.
12. Disassemble control panel or top and console assembly
(depending on application) and front panel assembly
from dryer to regain access to burner assembly.
13. Disconnect manometer and remove hose from
pressure tap.
14. Remove pressure tap.
15. Reinstall pressure tap plug to gas valve and tighten.
NOTE: Pressure tap plug can be reinstalled and securely
tighten to gas valve body without removal of the bulkhead
assembly with the use of a 3/16" hex wrench.
FIGURE 1
PRESSURE
TAP PLUG
GAS
VALVE
BODY
SIDE
VIEW
HOLE
7. If any bubbles are present, turn off gas supply, tighten
the leaking connection and retest for leaks.
8. If dryer was moved during conversion, use the same
method to check for leaks in the exible gas supply line
and ttings between the dryer and the gas supply pipe.
9. If any bubbles are present, tighten the leaking connection
and retest for leaks.
NOTE: Replace exible gas supply line if bubbles are present
on supply line.
10. If no bubbles are present, reinstall hole plug to side panel
and unplug dryer.
Checking for Leaks
1. With front panel removed, brush or spray an approved
non-corrosive leak detection solution onto pressure
tap plug.
2. Reassemble dryer in reverse order as described in
“Disassembling the Dryer.”
3. Turn on gas supply.
4. Plug in dryer or reconnect power.
5. Set dryer cycle to time dry, high heat and turn on dryer.
6. View through the hole on the right side panel inspecting
for leaks indicated by growing bubbles. See Figure 1.
Completing the Conversion
1. Check to assure all components are attached securely
in place and lint lter has been installed to dryer.
2. Reattach dryer top or top and console assembly (depending
on application). If dryer was moved from its original position,
reposition dryer to its location.
3. Connect external exhaust vent to dryer.
4. Plug in dryer or reconnect power.
5. Check that dryer is working properly by:
Turning on dryer.
Running on high heat for 5 minutes.
Checking for heat in drum.
Loading ...
Loading ...
Loading ...