NOTE: IF YOUR GAS DRYER HAS STYLE “A” FOLLOW STEP
6. FOR STYLE “B” SKIP TO STEPS 7 TO 10.
FIGURE 4
STYLE “B”
CAP – PERMANENTLY
FIXED TO VALVE
COVER DIAL
ONE-PIECE
COIL
3. Remove the burner orice from the gas valve assembly
and replace it with the proper orice furnished in this kit.
Orice number is stamped on one edge of the hex head
of orice. Securely tighten. See Figure 3.
Propane gas – Use Orice No. 55.
Butane gas – Use Orice No. .049.
FIGURE 3
ORIFICE
GAS VALVE
ASSEMBLY
4. Slide the burner tube back in place and, using the screws
removed in Section 3, step 8, reattach burner tube to the
burner assembly. Securely tighten the two (2) mounting
screws. See Figure 1A or 1B.
5. Before proceeding, you must rst determine which gas
valve style is on the dryer. Refer to Figure 4 – Style “A”
and “B”.
STYLE “B” GAS VALVE CONVERSION
7. Observe the cover dial settings indicated as NG (Natural
Gas) and LPG (Liqueed Propane gas) along with the gas
type setting indicator. See Figure 6.
8. Position a pair of bend pliers into the slots of the cover
dial. See Figure 7.
NOTE: To gain better access, remove the coil wire leads.
FIGURE 6
COVER DIAL
SETTING INDICATOR
“NG”
SETTING
“LPG”
SETTING
STYLE “A” GAS VALVE CONVERSION
6. Remove the regulator vent cap (leak limiting device)
from the pressure regulator. See Figure 5. Continue
to Step 10.
REGULATOR
VENT CAP
BLOCKING PIN
PRESSURE
REGULATOR
FIGURE 5
NOTE: If bend pliers are not available, a at-blade screwdriver
and/or needle nose pliers will sufce.
STYLE “A”
TWO
SEPARATE
COILS
REGULATOR
VENT CAP