Installation
97
EN
5 Installation
5.1 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate.
The identification plate bearing the
technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
The appliance operates at 220-240 V~.
Plug the appliance into a power socket
located around 1 - 1.5 metres from the
appliance.
Fixed connection
Fit the power line with an all-pole circuit
breaker in compliance with installation
regulations.
The all-pole circuit breaker should be
located near the appliance and in an easily
reachable position, according to
applicable electrical codes.
Connection with plug and socket
Make sure that the plug and socket are of
the same type. Avoid using adapters and
shunts as these could cause overheating
and a risk of burns.
5.2 Positioning
Power voltage
Danger of electrocution
Have the electrical connection
performed by authorised technical
personnel.
The appliance must be connected to
earth in compliance with electrical
system safety standards.
Disconnect the mains power supply.
Heavy appliance
Crushing hazard
Position the appliance into the cabinet
cut-out with the help of a second person.
To prevent hazards due to instability of
the appliance, this must be fastened in
accordance with the instructions.
Pressure on the open door
Risk of damage to the appliance.
Never use the oven door to lever the
appliance into place when fitting.
Avoid exerting too much pressure on the
oven door when open.
Heat production during appliance
operation
Risk of fire
Check that the carcase material is heat
resistant.
Check that the carcase has the required
openings.
Do not install the appliance in a recess
which can be closed with a door, or in a
cupboard.