Renogy 3500W PURE SINE WAVE 48V Inverter

User Manual - Page 8

For 3500W PURE SINE WAVE.

PDF File Manual, 40 pages, Read Online | Download pdf file

3500W PURE SINE WAVE photo
Loading ...
Loading ...
Loading ...
07
Load Output Working Modes
PV Priority
In this mode only the incoming solar energy and battery power are used to power the loads.
This can maximize the use of green energy when selecting PV priority in Battery Charging
Mode to achieve overall energy conservation and emission reduction. Upon there being no
more usable solar energy or the battery voltage drops to a low voltage setpoint, then the unit
will switch to utility power to continue to power up the loads. It is recommended to be in this
mode for relatively stable areas.
The solar inverter has 3 working modes that dictate how the incoming power is used to power
the loads.Users may configure the output source priority to configure load power.
CHARGING
CHARGING
CHARGING
Utility Priority
Equivalent to a backup UPS for use in unstable areas of the grid, Utility will provide power to
the loads as priority. Solar and battery energy will provide power to the loads only when utility
power is not available.
Inverter Mode
The Battery energy will supply power to the loads. Utility provides power to the loads only when
battery voltage drops to low voltage which maximizes the use of DC power.
Loading ...
Loading ...
Loading ...