15
Carefully place the correct AC wire into the respective AC Output terminal block. The ground
output cable will need to be connected to the ground screw terminal located separately from the
output terminal block. It is recommended to keep ground as close as possible to the solar
inverter charger, the shorter the ground wire, the better. The order should be as follows:
AC Output Wiring
Maximum Inverter
Bypass Current
Recommended
Wiring
Recommended
Circuit Breaker
40A 8AWG 2 pole, 40A
Only the Live and Neutral wires will be connected to the Output Terminal Block, the
Ground will be connected to the screw terminal.
Make sure any circuit breakers are disconnected and ensure the unit is in the off
position.
There are two terminal blocks with “IN” and “OUT” markings. Please do NOT
misconnect input and output connectors.
AC Output should NEVER be connected to public power/utility or a generator.
NOTE
NOTE
WARNING
CAUTION
Ground | LLive | NNeutral