27
*available in FLD
and USER setting
only
*available in FLD
and USER setting
only
*available in FLD
and USER setting
only
*available in FLD
and USER setting
only
*Power-saving
Mode (ECO Mode)
Parameters Number
Parameter Name Description
Set options
18
[18] 120min
(Default)
Setting range is from 5min to 900
min. , in 5min increments
Battery
Equalization
Duration
19
[19] 240min
(Default)
Setting range is from 5min to 900
min, in 5min increments
Battery
Equalization
Time-Delay
20
[20] 30 days
(Default)
Setting range is from 0 days to 30
days, in 1 day increments
Stops equalization charging
immediately
Starts Equalization charging
immediately
Equalization
interval
21
[21] ENA
[21] DIS
(Default)
Enable
Equalization
Immediately
22
[22] DIS
Default
[22] ENA
Disables power-saving mode
Power-saving
Mode
After a 5min delay from setting, the
inverter will enter a power saving
mode and detect the load size.
Loads greater than or equal to 50W,
will be powered by the solar inverter.
Otherwise, it will automatically stay in
a low detecting mode and not power
any loads under 50W
23
[23] DIS
[23] ENA
(Default)
Overload automatic restart is
disabled, and the unit will not turn
on the loads
Enables automatic restart if the
load shutdown output has
occurred. The unit attempts to
restart the output after 3 minutes
and After 5 attempts the unit will
not longer resume to turn on the
loads
Overload
auto-start
24
[24] DIS
Over-temperature automatic
re-start is disabled
The over-temperature protection
is activated and upon temperature
dropping, the unit automatically
restarts
Overtemperature
auto-start
[24] ENA
(Default)
Loading ...