34
When modifying parameters in User Mode, the following rules must be followed to set parameters
successfully.
If setting the Low Voltage Disconnect in User Mode, it must always be at least 2V lower than
the Low Voltage Disconnect Recovery Voltage
Overvoltage Disconnect > Overvoltage Disconnect Recover ≥ Equalization voltage ≥ Boost voltage
≥ Float voltage
Overvoltage Disconnect > Over Voltage Disconnect Recover
Low Voltage Disconnect Recover > Low Voltage Disconnect (at least 2V Smaller) < Discharge
Limit Voltage
Undervoltage Recover > Undervoltage Alarm
Over Voltage
Disconnect
Over Voltage
Disconnect Recover
Battery type
Parameters
USER
(Default)
Flooded
Lead Acid
(FLD)
Custom Range
SLD/
AGM
GEL
Non-Lithium Battery Parameters
Equalization
Voltage [16]
Boost Voltage
[09]
Under Voltage
recover
Low Voltage
Warning [14]
Low Voltage
Disconnect
Recover [35]
Low Voltage
Disconnect
[12]
Discharge Limit
Voltage [15]
58.2V
Over-discharge
Delay Time [13]
Float Voltage
[11]
60V
58.2V
60V
58.2V
59.2V
60V
58.2V
60V
N/A
44.8V 44.8V 44.8V 44.8V N/A
50.4V
50.4V 50.4V
50.4V
adjustable)
N/A
58.4V 56.8V 58.4V
58.4V
adjustable)
48~58.4V
55.2V 55.2V 55.2V
55.2V
adjustable)
48~58.4V
43.8V 43.8V 43.8V
43.8V
adjustable)
40~52V
42V 42V 42V
42V
adjustable)
38~50V
40V 40V 40V
40V
adjustable)
36~50V
5S 5S 5S
5S
adjustable)
5~50S
120
minutes
120
minutes
120
minutes
120 minutes
adjustable)
5~900 minutes
59.2V
adjustable)
48~59.2V
N/A
Equalization
Duration [18]
Equalization
Interval [20]
Boost Duration
[10]
- -
120
minutes
120 minutes
adjustable)
5~900 minutes
- -
30
days
30 days
adjustable)
0~30 days
- -