Dahua XVR5204A-I3 4CH Penta-brid 5MP Value/1080P 1U 2HDDs WizSense Digital Video Recorder

Compact&MINI HDD INSTALLATION GUIDE V1.0.2 - Page 339

For XVR5204A-I3.

PDF File Manual, 404 pages, Read Online | Download pdf file

XVR5204A-I3 photo
Loading ...
Loading ...
Loading ...
Parameter Description
Add
When Type is Network Access, you can congure IP
Address, IP Segment and MAC Address.
Type You can select IP address, IP segment and MAC address.
IP Address
Enter IP Address, Start Port and End Port that is allowed or
forbidden.
When Type is IP Address, they can be congured. Start
Port and End Port can be congured only in Network
Access Type.
Start Port
End Port
Start Address/End Address
Enter Start Address and End Address of IP Segment.
When Type is IP Segment, they can be congured.
MAC Address
Enter MAC Address that is allowed or forbidden
When Type is MAC Address, it can be congured.
Step 4 Click Apply.
5.19.3.2 Account Lockout
Procedure
Step 1 Select Main Menu > SECURITY > Attack Defense > Account Lockout.
Step 2 Set parameters.
Table 5-77 Lockout parameters
Parameter Description
Attempt(s)
Set the maximum number of allowable wrong password
entries. The account will be locked after your entries
exceed the maximum number.
Value range: 5–30.
Default value: 5.
Lock Time
Set how long the account is locked for.
Value range: 5–120 minutes.
Default value: 5 minutes.
Step 3 Click Apply.
User's Manual