Step 4 Congure the triggering parameters.
Table 5-49 Schedule and linkage parameters
Parameter Description
Schedule Dene a period during which the detection is active.
Alarm-out Port
Click Setting to congure the parameters.
●
General Alarm: Enable general alarm and select the alarm
output port.
●
External Alarm: Connect the alarm box to the Device and then
enable it.
●
Wireless Siren: Connect the wireless gateway to the Device and
then enable it.
When an alarm event occurs, the system links the peripheral
alarm devices connected to the selected output port.
Post-Alarm
Set a length of time for the Device to delay turning o alarm after
the external alarm is cancelled. The value ranges from 0 seconds
to 300 seconds. If you enter 0, there will be no delay.
Show Message
Select the Show Message checkbox to enable a pop-up alarm
message in your local host PC.
Report Alarm
Select the Report Alarm checkbox, and then click Setting next
to Report Alarm to select Private Protocol or HTTP in the
Protocol Type.
You can enable the system to upload the alarm signal to the
network (including alarm center) when an alarm event occurs.
●
This function is available on select models.
●
The corresponding parameters in the alarm center should be
congured.