The shutter is located at the end of the burner tubes closest to the gas orifice (See
“Figure 21” for further details).
Use a flashlight to view the screened openings of the air shutter from and remove any
obvious obstructions from the screen protecting the air shutter.
TO ADJUST THE AIR SHUTTER:
Leave the gas supply shutoff valve in the OFF position or leave the main valve on the LP
cylinder in the closed position. The grill control knobs should also remain in the OFF
position.