Page 18 of 64
NOTE TO GAS TECHNICIAN
WARNING: DO NOT perform any pressure tests on this appliance or the regulator supplied in
excess of 1/2 PSIG.
For fixed fuel supply systems. RE: Pressure tests
1.
The appliance and its individual shut-off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2
psi. (3.45 kPa).
2.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi. (3.45kPa).
WARNING: DO NOT install any gas handling components/materials affected by elevated
temperatures within 18 inches (45.7 cm) of any side of this appliance.
Make sure that the supply line is of adequate capacity to accommodate the higher inputs of the
grill before you begin. They are significantly higher inputs than average appliances of this type.
The use of a typical corrugated metallic appliance connector is recommended for connecting
the appliance, with a minimum inside diameter of 3/4”.
BTU’s
LP Pilot
Orifice - 70
BTU’s
LP Burner
Orifice - 56
BTU’s
NG Pilot
Orifice - 57
BTU’s
NG Burner
Orifice - 49
Total BTU’s
NG/LP
MCB30 (R)
5,000 (4,800)
15,000 (14,000)
5,000 (4,800)
15,000 (14,000)
65,000 (60,800)
MCB36 (R)
5,000 (4,800)
15,000 (14,000)
5,000 (4,800)
15,000 (14,000)
80,000 (74,800)
MCB42 (R)
5,000 (4,800)
15,000 (14,000)
5,000 (4,800)
15,000 (14,000)
95,000 (88,800)
MCB48 (R)
5,000 (4,800)
15,000 (14,000)
5,000 (4,800)
15,000 (14,000)
110,000 (102,800)
MCB60 (R)
5,000 (4,800)
15,000 (14,000)
5,000 (4,800)
15,000 (14,000)
130,000 (121,600)
MCB72 (R)
5,000 (4,800)
15,000 (14,000)
5,000 (4,800)
15,000 (14,000)
160,000 (149,600)
BTU Side Burners: Table 2
BTU’s
LP Burner
Orifice - 57
BTU’s
NG Burner
Orifice - 49
Total BTU’s
NG/LP
SB-MCB
15,000
15,000
15,000
Loading ...
Loading ...