37
A<-B: The alarm will be triggered when the intruder/vehicle crosses over the alarm line
from B to A.
Click the “Draw Area” button and then drag the mouse to draw a line in the image. Click the
Stop Draw” button to stop drawing. Click the “Clear” button to delete the lines. Click the
“Save” button to save the settings.
6. Set the schedule of the line crossing alarm. The setup steps of the schedule are the same
as the schedule recording setup (See 4.1.4.1 Schedule Recording Settings).
Configuration of camera and surrounding area
1. Auto-focusing function should not be enabled for line crossing detection.
2. Avoid the scenes with many trees or the scenes with various light changes (like many
flashing headlights). The ambient brightness of the scenes shouldn’t be too low.
3. Cameras should be mounted at a height of 2.8 meters or above.
4. Keep the mounting angle of the camera at about 45°.
5. The detected objects should not be less than 1% of the entire image and the largest sizes
of the detected objects should not be more than 1/8 of the entire image.
6. Make sure cameras can view objects for at least 2 seconds in the detected area for
accurate detection.
7. Adequate light and clear scenery are crucial for line crossing detection.