INSTALLATION INSTRUCTIONS
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local
codes do not allow grounding through neutral, New Branch circuit installations (1996
NEC), mobile homes and recreational vehides, new construction and in Canada.
1. Connect the 2 black wires (B) together
using a UL listed wire connector.
2. Connect the 2 red wires (C) together using
a UL listed wire connector.
3. Untwist white wire from green (or bare)
ground wire coming from the oven
4. Connect the 2 white wires (F) together using
a UL listed wire connector.
5. Connect the green (or bare) ground wire (H)
from the oven cable to the green (or bare)
ground wire (in the junction box) using a
UL listed wire connector.
6. Install junction box cover
A. Cable from home power supply
B. Black wires (normally L1)
C. Red wires (normally L2)
D. 4-wire flexible conduit from oven
E. Junction box
F. White wires (normally N-neutral)
G. UL listed wire connectors
H. green wires (normally Gijround)
I. UL listed or CSA approved conduit
connector.