Enable to join IGMP Querier election in the VLAN. Disable to act as an IGMP Non-Querier.
Compatibility :
Compatibility is maintained by hosts and routers taking appropriate actions depending on
the versions of IGMP operating on hosts and routers within a network. The allowed selection
is IGMP-Auto, Forced IGMPv1, Forced IGMPv2, Forced IGMPv3, default compatibility value is
IGMP-Auto.
Rv :
Robustness Variable. The Robustness Variable allows tuning for the expected packet loss on
a network. The allowed range is 1 to 255; default robustness variable value is 2.
QI(sec) :
Query Interval. The Query Interval is the interval between General Queries sent by the
Querier. The allowed range is 1 to 31744 seconds; default query interval is 125 seconds.
QRI(0.1 sec) :
Query Response Interval. The Max Response Time used to calculate the Max Resp Code
inserted into the periodic General Queries. The allowed range is 0 to 31744 in tenths of
seconds; default query response interval is 100 in tenths of seconds (10 seconds).
LLQI (0.1 sec) :
Last Member Query Interval. The Last Member Query Time is the time value represented by
the Last Member Query Interval, multiplied by the Last Member Query Count. The allowed
range is 0 to 31744 in tenths of seconds; default last member query interval is 10 in tenths
of seconds (1 second).
URI(sec) :
Unsolicited Report Interval. The Unsolicited Report Interval is the time between repetitions
of a host's initial report of membership in a group. The allowed range is 0 to 31744 seconds,
default unsolicited report interval is 1 second. .
Buttons
Apply :
Click to save changes.
Reset :
Click to undo any changes made locally and revert to previously saved values.