166 ALEXA SXT Studio
Attaching the optical viewfinder
Upon delivery, the OVF is not connected to the camera and must be installed by the
user.
1. Remove the protective cover from the OVF by loosening its 2x 3mm hex socket
head screws.
2. Remove the cover plate from the camera by loosening its 2x 3mm hex socket
head screws.
3. Place the OVF on the camera.
4. Take special care that the electronic connectors of camera and viewfinder are
connected before pushing the OVF in place.
5. Tighten the 3x 3mm hex socket head screws of the OVF (See OVF top view image
for locations of screws).
NOTICE
The torx screws on the camera that are painted red must not be tightened or
loosened, as this would corrupt the alignment of the OVF.
Fig. 61: OVF with cover plate
Fig. 62: Alexa Studio with cover plate
NOTICE
When recording in Open Gate mode, the image shown by the optical viewfinder is
smaller than the image that is actually recorded. For exact framing, use the EVF-1
or a monitor connected to MON OUT.
Loading ...