4. Screw the ARRI Ground Glass Puller into the ground glass.
5. Carefully pull out the ground glass.
6. Check that the new ground glass and the ground glass holder are clean.
7. Screw the ARRI Ground Glass Puller into the new ground glass and push it into
the holder.
8. Make sure the ground glass is inserted completely and correctly locked in place.
9. Unscrew the ground glass puller from the ground glass.
10. Attach a lens or a protective cap to the lens mount.
Fig. 56: Ground glass in camera with Ground Glass Puller attached
Fig. 57: Ground glass with attached Ground Glass Puller
To remove the field lens, which is located above the ground glass:
1. Remove the ground glass first
2. Screw the ARRI Ground Glass Puller into the field lens