STACKED
WASHER/GAS
DRYER
INSTALLATION
REQUIREMENTS
Stacked
Washer/Gas
Dryer
Gas
Supply
Requirements
EL
te
Explosion
Hazard
Connect
this
dryer
to
a
regulated
gas
supply.
Supply
pressure
must
be
in
accordance
with
the
Technical
Specifications.
Install
a
shut-off
valve.
Securely
tighten
all
gas
connections.
if
connected
to
LP,
have
a
qualified
person
make
sure
gas
pressure
is
correct.
Failure
to
do
so
can
result
in
death,
explosion,
or
fire.
IMPORTANT:
Observe
all
governing
codes
and
ordinances.
In
Australia
and
New
Zealand,
refer
to
AS/NZS
5601.1
-
Gas
Installations.
Gas
Supply
Before
installation,
check
that
the
local
gas
distribution
conditions,
nature
of
gas
and
pressure,
and
the
adjustment
of
the
appliance
are
compatible.
Burner
information
will
be
found
on
the
mocdel/
serial
rating
plate
in
the
door
recess
of
the
dryer.
If
this
information
does
not
agree
with
the
type
of
gas
available,
see
your
dealer.
Natural
Gas:
This
dryer
is
factory
adjusted
for
use
with
NATURAL
GAS
(G20),
and
no
further
adjustment
should
be
required
at
installation.
L.P.
Gas:
This
dryer
is
also certified
for
use
with
LP.
(propane
or
butane)
gases
with
appropriate
conversion.
No
attempt
shall
be
made
to
convert
the
appliance
from
the
gas
specified
on
the
model/serial
rating
plate
for
use
with
a
different
gas
without
consulting
the
serving
gas
supplier.
Conversion
must
be
done
by
a
competent
service
technician.
Gas
conversion
kit
(European
Country),
part
number
W10233219,
is
available
for
purchase
from
your
dealer.
Gas
conversion
kit
(Australia),
part
number
W10315369,
is
available
for
purchase
from
your
dealer.
Full
instructions
are
supplied
with
the
kit.
Natural
gas
(France/
Belgium):
This
dryer
is
also certified
for
France/Belgium
for
use
with
G20/
G25
gases
(20
mbar/25
mbar)
with
appropriate
conversion.
No
attempt
should
be
made
to
convert
this
appliance
from
the
gas
specified
on
the
gas
rating
label
for
use
with
a
different
gas
without
consulting
the
serving
gas
supplier.
Gas
conversion
must
be
done
by
a
qualified
gas service
technician.
Conversion
kit,
part
number
(W10181947)
is
available
for
purchase
from
your
dealer.
Full
instructions
are
supplied
with
the
kit.
12
Supply
line
requirements:
Provide
a
rigid
gas
supply
line
to
the
washer/dryer
location.
It
should
be
minimum
12.5
mm
(1/2")
ID.
When
acceptable
to
the
gas
supplier
and
local
codes,
10
mm
(3/8")
ID
rigid
supply
line
may
be
used
for
lengths
under
6.1
m
(20').
Pipe-joint
compounds
resistant
to
the
action
of
L.P.
gas
must
be
used.
NOTE:
For
installation
in
Australia
and
New
Zealand,
refer
to
AS/NZS
5601
for
pipe
sizing
details.
All
piping
is
to
be
in
accordance
with
AS/NZS
5601.1
-—
Gas
Installations.
Gas
connection
to
the
dryer
itself
should
be
made
by
means
of
a
flexible
gas
hose
suitable
for
the
appliance
and
gas
category
in
accordance
with
national
installation
regulations.
If
in
doubt,
contact
the
gas
supplier.
It
should
be
minimum
10
mm
(3/8")
ID.
A
means
of
restraint
should
be
used
between
the
washer/dryer
and
the
wall
to
avoid
straining
of
the
rigid
gas
supply
when
the
washer/dryer
is
moved.
An
appropriate
length
of
chain
and
a
wall
hook
is
recommended.
The
dryer
gas
inlet
connection
is
a
3/8"
NPT
thread.
An
adapter
is
supplied
for
conversion
to
standard
|SO.228-1
thread
(3/8"
BSP).
Check
for
leaks
by
using
an
approved
noncorrosive
leak-detection
solution.
Bubbles
will
show
a
leak.
Correct
any
leak
found.
A
pressure
measurement
tapping
is
provided
on
the
gas
valve
within
the
dryer,
accessible
after
removal
of
the
lower
front
panel.
The
dryer
must
be
disconnected
from
the
gas
supply
piping
system
during
any
pressure
testing
of
that
system.