SiUS121827E RA Indoor Unit Functions
Part 4 Functions and Control 69
2.7 ECONO Operation
Outline ECONO operation reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving. It is also a major bonus when breaker
capacity does not allow the use of multiple electrical devices and air conditioners.
It can be easily activated by pressing ECONO button on the wireless remote controller.
Details When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in cooling, heating, dry,
or automatic operation. This function can only be set when the unit is running. Pressing ON/OFF
button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest command
has the priority.
ECONO operation
(R22012)
Normal operation
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current