SiUS121827E Specifications
Part 2 Specifications 31
1.2 SA Indoor Unit
Model FDMQ09RVJU FDMQ12RVJU
Cooling Heating Cooling Heating
Power Supply Phase 1 φ 1 φ
Hz, V 60 Hz, 208 - 230 V 60 Hz, 208 - 230 V
Rated Capacity 9 kBtu/h Class 12 kBtu/h Class
Casing Color
Dimensions (H × W × D) in. (mm) 9-5/8 × 27-9/16 × 31-1/2 (245 × 700 × 800) 9-5/8 × 27-9/16 × 31-1/2 (245 × 700 × 800)
Coil Type Cross Fin Coil Cross Fin Coil
Rows × Stages × Fin per Inch 3 × 26 × 18 3 × 26 × 18
Face Area ft² (m²) 1-15/16 (0.178) 1-15/16 (0.178)
Fan Type Sirocco Fan Sirocco Fan
Motor Output W 130 130
Airflow Rate
H / M / L
cfm
(m
3
/min)
343 / 290 / 240
(9.7 / 8.2 / 6.8)
343 / 290 / 240
(9.7 / 8.2 / 6.8)
392 / 332 / 275
(11.1 / 9.4 / 7.8)
392 / 332 / 275
(11.1 / 9.4 / 7.8)
External Static
Pressure 1
inH
2
O 0.20 (0.60 - 0.12) 0.20 (0.60 - 0.12)
Pa 50 (150 - 30) 50 (150 - 30)
Sound Pressure Level dB(A) 32 32 33 33
Sound Power Level dB(A) 46 46 47 47
Air Filter 2—
Weight (Mass) Lbs (kg) 64 (29) 64 (29)
Piping
Connection
Liquid in. (mm) φ 1/4 (φ 6.4) (Flare) φ 1/4 (φ 6.4) (Flare)
Gas in. (mm) φ 3/8 (φ 9.5) (Flare) φ 3/8 (φ 9.5) (Flare)
Drain in. (mm) I.D. φ 1 (φ 25) / O.D. φ 1-1/4 (φ 32) I.D. φ 1 (φ 25) / O.D. φ 1-1/4 (φ 32)
Remote
Controller
(Option)
Wired BRC1E73 BRC1E73
Wireless
BRC082A43 BRC082A43
Drawing No. 3D112997C 3D112997C
Notes 1. External static pressure is changeable in 13 stages
by remote controller.
2. Air filter is not standard accessory, but please mount
it in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50%
or more.
1. External static pressure is changeable in 13 stages
by remote controller.
2. Air filter is not standard accessory, but please mount
it in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50%
or more.
Model FDMQ15RVJU FDMQ18RVJU
Cooling Heating Cooling Heating
Power Supply Phase 1 φ 1 φ
Hz, V 60 Hz, 208 - 230 V 60 Hz, 208 - 230 V
Rated Capacity 15 kBtu/h Class 18 kBtu/h Class
Casing Color
Dimensions (H × W × D) in. (mm) 9-5/8 × 39-3/8 × 31-1/2 (245 × 1,000 × 800) 9-5/8 × 39-3/8 × 31-1/2 (245 × 1,000 × 800)
Coil Type Cross Fin Coil Cross Fin Coil
Rows × Stages × Fin per Inch 2 × 26 × 18 3 × 26 × 18
Face Area ft² (m²) 3-1/8 (0.288) 3-1/8 (0.288)
Fan Type Sirocco Fan Sirocco Fan
Motor Output W 230 230
Airflow Rate
H / M / L
cfm
(m
3
/min)
516 / 438 / 360
(14.6 / 12.4 / 10.2)
516 / 438 / 360
(14.6 / 12.4 / 10.2)
675 / 572 / 473
(19.1 / 16.2 / 13.4)
675 / 572 / 473
(19.1 / 16.2 / 13.4)
External Static
Pressure 1
inH
2
O 0.20 (0.60 - 0.20) 0.20 (0.60 - 0.12)
Pa 50 (150 - 50) 50 (150 - 50)
Sound Pressure Level dB(A) 34 34 35 35
Sound Power Level dB(A) 48 48 49 49
Air Filter 2—
Weight (Mass) Lbs (kg) 77 (35) 82 (37)
Piping
Connection
Liquid in. (mm) φ 1/4 (φ 6.4) (Flare) φ 1/4 (φ 6.4) (Flare)
Gas in. (mm) φ 1/2 (φ 12.7) (Flare) φ 1/2 (φ 12.7) (Flare)
Drain in. (mm) I.D. φ 1 (φ 25) / O.D. φ 1-1/4 (φ 32) I.D. φ 1 (φ 25) / O.D. φ 1-1/4 (φ 32)
Remote
Controller
(Option)
Wired BRC1E73 BRC1E73
Wireless
BRC082A43 BRC082A43
Drawing No. 3D112997C 3D112997C
Notes 1. External static pressure is changeable in 11 stages
by remote controller.
2. Air filter is not standard accessory, but please mount
it in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50%
or more.
1. External static pressure is changeable in 11 stages
by remote controller.
2. Air filter is not standard accessory, but please mount
it in the duct system of the suction side.
Select its dust collection efficiency (gravity method) 50%
or more.
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3