1311298 Daikin Dual-Zone Mini Split System with with 47000 BTU Cooling Capacity, 48500 BTU Heating Capacity and 2x Wall Mounted Indoor Units

User Manual - Page 70

For 1311298.

PDF File Manual, 299 pages, Read Online | Download pdf file

1311298 photo
Loading ...
Loading ...
Loading ...
RA Indoor Unit Functions SiUS121827E
64 Part 4 Functions and Control
Note(s)
2.2 Fan Speed Control for Indoor Unit
Outline Phase control and fan speed control contains 9 steps: LLL, LL, SL, L, ML, M, MH, H, and HH.
The airflow rate can be automatically controlled depending on the difference between the room
thermistor temperature and the target temperature.
Automatic Fan
Speed Control
In automatic fan speed operation, the step SL is not available.
R4003512
= The airflow rate is automatically controlled within this range when FAN setting button is set
to automatic
.
Cooling
The following drawing explains the principle of fan speed control for cooling.
The upper limit is at M tap in 30 minutes from the operation start.
Heating
In heating operation, the fan speed is regulated according to the indoor heat exchanger
temperature and the difference between the room thermistor temperature and the target
temperature.
The fan stops during defrost operation.
COMFORT
AIRFLOW
Operation
FTXR, CTXG, CTXS, FTXS Series
The fan speed is controlled automatically within the following steps.
Cooling
L tap ~ MH tap (same as AUTOMATIC)
Heating
In order to obtain a comfortable airflow, the fan speed may be set to a rate different from
automatic fan speed control.
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
HeatingCoolingStep
LLL
LL
L
ML
M
MH
H
HH (POWERFUL)
(R21654)
+2.5°C (+4.5°F)
+1.5°C (+2.7°F)
+0.5°C (+0.9°F)
MH*
M
ML
L
+3°C (+5.4°F)
+2°C (+3.6°F)
+1°C (+1.8°F)
Fan speed
Room thermistor temperature – target temperature
Loading ...
Loading ...
Loading ...