Loading ...
Loading ...
Loading ...
920-087-04 (8-05)
WallSleeveInstallation Instructions(PDXWS)
NOTE: Insurethatthe unitisonlyinstalledin awallstructurallyadequatetosupport the unitincludingthesleeve,chassisand accessories.
If the sleeve projects more than 8"into the room, a subbase orother means of support MUST be used. Please readthese instructions
completely before attempting installation.
Figure5
Typical Wall Sleeve Installation
Lintel to support masonry
J
16W' Electrical receptacle
Electrical
10 _
(25.4 cm)
m_
Wall opening
Wall sleeve --
insulation--
Smooth side of screw
clip facing into room
Note: All 230/208V units are manufactured with a 60" power cord. The receptacle
locations above must be followed to ensure proper connections.
ForDeep Wall Installation See Section II
The following instructions apply ONLY to walls less than
13 1/4" indepth.
1. From inside the building, position the wall sleeve in the
opening and push itthrough the wall so it protrudes at least
1/4"on the outside, note Figure 5.
,
Position the wall sleeve with a slight tilt towards the outside
tofacilitate condensate drainage. Itshould be levelside-to-
sideand thefront should be 1!4bubble higherthan theback.
DO NOT allow any pitch toward the inside.
Electrical shock hazard.
Turn electric power OFF at the fuse box or service panel
before making any electrical connections and ensure a
proper ground connection is made before connecting line
voltage. Failure to do so can result in property damage,
personal injury and/or death.