Siglent SPS5081X 80V/15A/360W Single Channel Switch Mode Power Supply

Manual - Page 79

For SPS5081X.

PDF File Manual, 94 pages, Read Online | Download pdf file

SPS5081X photo
Loading ...
Loading ...
Loading ...
SPS5000X Series User Manual
WWW.SIGLENT.COM 78
Response: 1\n
Set external output enable state
Command format: [:SOURce]:OUTPut:LOCAL:ENable (CHn) , {ON | OFF | 0 | 1}
Description: Set the external output enable state of the selected channel
(ON | OFF | 0 | 1)
E.g: OUTPut:LOCAL:ENable CH1,0
Description: Set CH1 channel to external control mode
Command format: [:SOURce]:OUTPut:LOCAL:ENable? (CHn)
Description: Get the external output enable status of the selected channel
E.g: OUTPut:LOCAL:ENable? CH1
Response: 1\n
Set internal resistance
Command format: [:SOURce]:INIT:RESIstance (CHn) ,{<value> | MINimum | MAXimum
|DEFault}
Description: Set the internal resistance of the selected channel
E.g: INIT:RESIstance CH1,2
Description: Set the internal resistance of CH1 channel to 2Ω
Command format: [:SOURce]:INIT:RESIstance? (CHn)
Description: Get the internal resistance value of the selected channel
E.g: INIT:RESIstance?
Response: 2.000000\n
Set channel CC/CV priority mode
Command format: [:SOURce][:CVCC]:PRIOrity (CHn) ,{CC | CV }
Description: Set the CC/CV priority of the selected channel (CC | CV)
E.g: PRIOrity CH1,CC
Description: Set the operation mode to CC priority
Command format: [:SOURce][:CVCC]:PRIOrityq? (CHn)
Description: Get the CC/CV priority of the selected channel
Loading ...
Loading ...
Loading ...