WWW.SIGLENT.COM 57
Set Measurement Accuracy
The SPS5000X has three measurement accuracy modes to choose from: Low,
Mid and High. When Low is selected, the measurement rate is the fastest but
has less accuracy. High is the slowest measurement, but more accuracy. High
is selected by default.
Setting method: Menu 2.Configure 6.Measure average to enter the
setting interface. Press the knob in the interface, turn the knob to switch the
cursor, press the knob to confirm and the setting takes effect.
External Analog Control
Four working modes of voltage control voltage, voltage control current,
resistance control voltage, and resistance control current can be realized
through the ports on the rear panel. In the external voltage control mode, an
adjustable voltage of 0-10 V is connected to the input terminal to simulate the
output from 0 to full-scale, to adjust the value of the voltage and current output
by the power supply (10 V corresponds to the voltage or current value of the
full-scale of the power supply).
External voltage control voltage output
Setting method: Menu → 2.Configure 7.Voltage control, press the knob
or the Set button to enter the setting interface, then press the knob or
the Set button to enter the selection, and press the knob or turn the knob
to select and then press the knob or the Set button to confirm .
Load
DC
SPS5000X
+
-
Analog
connector
DC
V_PROG_
Voltage
0-10V
2 core shielded
wire or twisted pair
2
4
External voltage control voltage output
Loading ...