85
Table 13-1 LED Description
LED
Color
Description
Status
LED
Flashing Green
The tester is communicating via USB cable.
Flashing Blue
The tester is communicating via Bluetooth.
Flashing Red
Battery clamps are connected to the wrong battery
terminals.
Power
LED
Solid Green
The tester is powered on and the battery is sufficiently
charged.
Flashing Green
The tester is charging. (Turns solid green when
battery is fully charged.)
Solid Red
The device is in boot mode.
Flashing Red
The battery level is low. Please charge.
Power Sources
The MaxiBAS BT506 tester can receive power from the following sources:
Internal battery pack
AC/DC power supply
IMPORTANT
Do not charge the battery when the temperature is below 0 °C (32 °F) or above 45 °C
(113 °F).
Internal Battery Pack
The MaxiBAS BT506 tester can be powered with the internal rechargeable battery.
AC/DC Power Supply Using Power Adapter
The MaxiBAS BT506 tester can be powered from an electrical outlet using the AC/DC
power adapter. The AC/DC power supply also charges the internal battery pack.