25
Minimum Clearances
When the upright cooker is installed abutting a side or rear wall, the wall must be
of non-combustible material, eg ceramic tiles. The following minimum clearances
to combustible materials must be observed:
• Minimumclearancefromhotplatetosidewallmustbe200mm.
• Minimumclearancefromhotplatetorearwallmustbe200mm.
• Minimumclearancefromhotplatetocupboardabovehobburnersmustbe600mm.
It is recommended that the adjacent kitchen surfaces should be capable of withstanding
temperatures of 100°C.
INSTALLATION INSTRUCTIONS
These instructions are for the use of a qualified installer only
Statutory regulations
This appliance is to be installed in accordance with the manufacturer’s installation
instructions, local gas fitting regulations, applicable building codes, electrical wiring
regulations, and according to the installation code for Gas Appliances AS5601/AG6O1.
Consult SAA wiring rules as appropriate.
Safety Warnings About Installation
• Thecookermustbeinstalledandservicedbyaqualiedtechnician.
• Acerticateofcompliancemustbesuppliedbytheinstallerandkept
by the customer.
• Allpackagingmaterialsincludingprotectiveplasticlmmustberemoved
before the cooker is installed.
• Thepipesusedininstallationmusthavesufcientloopstoallowforthe
cooker to be moved for service.
• Thesafetychainmustbetted.
• Thecookermustnotbeliftedorpulledusingtheovenhandle
• Thecookermustbeservicedandcheckedevery3to4yearsdepending
on usage or condition.